Explore Perfect Tents Under the Stars
Explore Perfect Tents Under the Stars Explore Perfect Tents Under the Stars
Cart(0)
Home Hiking Equipment Daypacks
Product Details
Server Technology PRO2 Switched PDU C2W48TE-YCMFAM99 - Master - power distribution unit (rack-mountable) - AC 208 V - 8.6 kW - 3-phase - Ethernet 10/100, RS-232 - input: NEMA L21-30P - output connectors: 51 (30 x IEC 60320 C13, 3 x NEMA 5-20R, 18 x IEC 60320 Cx)

  • HDOT CX
    Cx is the future ready UL tested hybrid of the C13 and C19 outlets accommodating both C20 and C14 plugs.
  • Network monitoring
    Gain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
  • Hot swappable
    Network access is ensured when power is lost to the Master unit with backup power provided by the primary link unit.
  • Multi link expansion
    Provides the ability to link up to four power circuits using one IP address. Primary link provides backup power to network card.
  • Enviromental monitoring
    Master and Link units each support two external 10' (3m) T/H probes. Receive SNMP-based alerts and email notifications.
  • Input current monitor
    Easy-to-read LEDs display current per phase to help prevent overloads and simplify three-phase load balancing in high-density cabinets.
  • Per-inlet power sensing
    Meets ANSI C12.1 for billing-grade accuracy of Current per phase. PIPS includes voltage, active power, apparent power, power factor, and energy.
  • Branch current monitoring
    PRO2 monitors current at each breaker branch and provides SNMP-based alerts and emails on high usage that risks a tripped circuit.
  • Branch circuit protection
    This PDU meets the UL and IEC 60950-1 requirement for branch circuit protection through use of UL489 rated magnetic-hydraulic circuit breakers or UL248 fuses.
  • Outlet control
    On Switched rack PDUs, cycle power to individual outlets or groups of outlets to reboot servers. Or, power off unused receptacles.
  • Alternating-phase outlets
    3-phase power is wired in an alternating fashion per outlet for simplified load balancing, reduced cord lengths, and better airflow.
  • High retention outlets
    Receptacles have high retention and are compatible with P-Lock type power cords.
  • High temperature rating
    This product has been tested and approved for safe and reliable operation in 60 °C data center environments.
  • Flexible mounting
    Includes standard button mounts along with provisions for custom mounting brackets (contact Server Technology for details).
The Server Technology PRO2 Switched PDU provides control of outlet power and local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while installing equipment into the rack/cabinet. The integral PIPS technology provides billing-grade accurate measurement of current, voltage, active power, apparent power, power factor, crest factor, and accumulated energy at the input. These power data points, along with temperature and humidity measurements (provided via optional probes), are accessible through the built-in Web and CLI interfaces as well as through SNMP.
  • HDOT CX
  • Network monitoring
  • Hot swappable
  • Multi link expansion
  • Enviromental monitoring
  • Input current monitor
  • Per-inlet power sensing
  • Branch current monitoring
  • Branch circuit protection
  • Outlet control
  • Alternating-phase outlets
  • High retention outlets
  • High temperature rating
  • Flexible mounting
Server Technology PRO2 Switched PDU C2W48TE-YCMFAM99 - Master - power distribution unit (rack-mountable) - AC 208 V - 8.6 kW

$ 88.96

$ 68.43

Please select combo product attributes
The combo subtotal is $,SAVE$
Unavailable
You May Also Like
Cart
Explore Perfect Tents Under the Stars
Your cart is currently empty.